Menu
HomeElectrical ServicesHouse RewiresEV Charger InstallationConsumer Unit UpgradesOutdoor & Garden LightingCCTV InstallationCommercial ElectricalEICR / Electrical TestingShop Fit-Out ElectricsEmergency ElectricianLighting InstallationKitchen & Bathroom ElectricsFault FindingMedia Wall ElectricsOur WorkAbout UsReviewsContact
Electrical services
House RewiresEV Charger InstallationConsumer Unit UpgradesOutdoor & Garden LightingCCTV InstallationCommercial ElectricalEICR / Electrical TestingShop Fit-Out ElectricsEmergency ElectricianLighting InstallationKitchen & Bathroom ElectricsFault FindingMedia Wall Electrics
Areas covered
BearsdenMilngavieGlasgow West EndGlasgow SouthsidePaisleyClydebankGiffnock & Newton MearnsEast Kilbride Get a free quote Call 07502 547831

Our work

Electrical projects across Glasgow

Rewires, consumer units, lighting schemes, outdoor lighting, CCTV, EV charging, media walls and commercial fit-outs. Filter by the kind of work you are planning.

EV Chargers Pod Point EV charge point installed on a rendered house wall in Glasgow with the charging cable coiled

Pod Point EV charge point

Wall-mounted Pod Point charger on a dedicated RCD-protected radial, with the supply, main fuse and earthing arrangement assessed before install.

Rewires Cables chased into a solid brick wall during a house rewire first fix in Glasgow

Rewire first fix

Cable runs chased into solid walls and dressed in before plastering, planned room by room so the property stays usable.

Outdoor Lighting Garden at night lit by recessed wall lighting, fence lights and planted bed lighting in Glasgow

Garden lighting scheme

Zoned exterior scheme lighting the retaining wall, planting and steps, on armoured cable with a dusk photocell.

Media Walls Slatted timber media wall with wall-mounted TV, floating unit and concealed LED lighting in a Glasgow living room

Slatted media wall

Slatted panelling with a recessed screen, floating unit and concealed LED. Power, data and audio fed behind the panel at first fix.

CCTV CCTV dome camera installed under the eaves of a sandstone building in Glasgow by MMM Electrical, with the camera cable run in surface conduit down the elevation

CCTV camera installation

Hard-wired PoE camera positioned and angled for usable identification rather than a wide view that shows only that something happened.

Commercial Commercial ceiling first fix with lighting and power cabling run above the grid

Commercial ceiling first fix

Lighting, power and data first fix across a full floor before the suspended ceiling grid went in.

Lighting Recessed linear LED strips set into dark microcement walls and ceiling above a staircase

Linear lighting, stairwell

Recessed linear LED set into microcement, planned around the flight, the landing and the door head.

Kitchen & Bathroom Bathroom with an illuminated round mirror, ceiling pendant and shower enclosure

Bathroom lighting

Zone-compliant bathroom lighting with an illuminated mirror, extractor and IP-rated fittings throughout.

EV Chargers Electric vehicle connected to a home EV charge point installed by MMM Electrical at a property near Glasgow

Vehicle on charge

A second install on a rural property, commissioned and set up on the owner’s app before we left site.

Consumer Units Newly installed metal-clad consumer unit with individual RCBO protection in a Glasgow property

Consumer unit upgrade

Metal-clad board on individual RCBOs, every circuit tested before and after, labelled and certified the same day.

Outdoor Lighting Garden bollard light being wired during an outdoor lighting installation in Glasgow

Garden bollard lighting

Bollard lights wired on steel wire armoured cable at depth, glanded properly and RCD protected.

Commercial Control panel wired out with terminal rails and cabling before installation

Control panel wiring

Panel built and wired out on the bench, then installed and commissioned on site.

CCTV CCTV recorder and monitor installed in a comms rack by MMM Electrical, showing a live multi-camera view alongside power supplies

CCTV recorder and monitoring

Recorder, monitor and camera power supplies installed in a rack, cameras terminated and the system commissioned on site.

Shop Fit-Outs Stainless steel commercial kitchen during fit-out with equipment supplies being installed

Commercial kitchen fit-out

Equipment supplies, extraction and back-of-house power for a hospitality fit-out.

Consumer Units Consumer unit open during installation showing circuit breakers and wiring in Glasgow

Board install in progress

Existing circuits tested before anything is disconnected — a board change onto faulty wiring only moves the problem.

Rewires Core-drilled cable entry through sandstone during a rewire in Glasgow

Core-drilled cable entry

Cable taken through sandstone on a core drill rather than hacked through, then made good.

Lighting Staircase lit by recessed linear lighting on the surrounding walls

Stair lighting

Lighting to the flight with a dimmed overnight level, so the stairs are usable without lighting the whole hall.

Outdoor Lighting Exterior bulkhead wall light installed on a rendered house elevation

Exterior wall lighting

Exterior wall lighting to a rendered elevation, IP-rated and photocell controlled.

Media Walls Media wall with floating unit and warm concealed lighting installed by MMM Electrical in Glasgow

Media wall and floating unit

Wall-hung unit with warm under-lighting, screen and speaker cabling concealed before boarding.

Lighting Recessed step lighting picking out the treads of a staircase

Step lighting

Recessed step lighting picking out each tread, switched from both the hall and the landing.

Rewires Cable entry sealed through brickwork during electrical first fix in Glasgow

Cable entry through brickwork

Supply taken through the outer skin and sealed, part of a first fix on an older Glasgow property.

Outdoor Lighting Exterior light fitting and weatherproof junction box on a house wall in Glasgow

Outdoor lighting and junction

Exterior fitting and weatherproof junction on an IP-rated, RCD-protected circuit.

Case study

Consumer unit upgrade, Dennistoun

A first-floor tenement flat with the original rewireable fuse board still in place: no RCD protection anywhere in the property, a plastic enclosure, and main earthing that had never been upgraded from the day it went in.

Every circuit was tested before anything was disconnected, which is the step that decides whether a board swap is enough on its own. Insulation resistance came back healthy across all six circuits, so the existing wiring stayed. The board was replaced with a metal-clad 10-way unit on individual RCBOs with surge protection, the main earthing conductor was upsized, and protective bonding was run to the gas and water services.

Retested, labelled, and certified the same day. Power was off for around four hours in total.

Job sheet

  • Property — 1-bed tenement flat, Dennistoun
  • Removed — rewireable fuse board, plastic enclosure, no RCD
  • Fitted — metal-clad 10-way board, individual RCBOs
  • Added — Type 2 surge protection
  • Earthing — main conductor upsized, bonding to gas and water
  • Circuits tested — 6, before and after
  • Time on site — one day, ~4 hours without power
  • Issued — Electrical Installation Certificate with full schedules

Free quotes · No obligation

Planning work like this?

Send a couple of photos on WhatsApp and we will tell you what it involves and what it costs.